Tramont Weather Protective Gen-set Housings & Enclosures
Steel housings and enclosures with modular panel construction that protect your gen-set from the elements.
Standard Features:
-
Interchangeable modular panel construction: Allows design flexibility without compromising building standards.
-
Bolted panels: Facilitate service, future modification, upgrades or field replacement.
-
Fixed air inlet louvers: Sized for maximum radiator-cooling airflow.
-
Punched air outlet grid: Accommodates largest gen-set radiator (high ambient) within enclosure model gen-set group.
-
Punched air louvers: Accommodates alternator cooling air to eliminate dead spots.
-
Radiator ducted to enclosure air outlet: Prevents air recirculation within the enclosure.
-
Pitched (16:1) enclosure roof: Prevents water accumulation.
-
Heavy-gauge steel construction: Provides a durable, dent resilient structure.
-
Powder-baked paint: Creates a tough, scratch resistant finish (available in a wide selection of colors).
-
Lift off door hinges and radiator fill panel: Enable easy service access.
-
Stainless steel hinges and latches: Endure through harsh weather conditions.
-
Recessed and lockable door handles: Minimize potential damage.
-
Rubber sealed access doors: Prevent water infiltration and minimize noise.
Options and Accessories
-
Stainless steel, Aluminum, or Galvaneal construction.
-
High wind certification
-
Gravity air outlet louver
-
Motorized air intake louver
-
Motorized air outlet louver
-
120 VAC interior lighting with on/off switch
-
AC load center 120/240 single phase
-
DC light package
-
Plexiglas panel viewing window
-
Sub base and cross member for generator set
-
Motorized variable damper (air inlet and air outlet)
-
Enclosure heater
-
Fuel transfer system
-
Load banks
-
Door holders
Tramont Enclosure 75dBA Sound Attenuated
Steel enclosure with formed panel construction that protects your gen-set from the elements and provides 75dBA sound attenuation at 23 feet.
Standard Features:
-
90° vertical air outlet hood: Redirects airflow to reduce noise.
-
Acoustic insulation listed to UL-94 HF1 for flammability.
-
Formed panel construction: Allows design flexibility without compromising building standards.
-
Bolted panels: Facilitate service, future modification, upgrades or field replacement.
-
Radiator ducted to enclosure air outlet: Prevents air recirculation within the enclosure.
-
Punched air inlet features internal baffle to minimize rain intrusion and is sized for maximum cooling airflow.
-
Punched air louvers: Accommodate alternator cooling air.
-
Pitched enclosure roof: Prevents water accumulation.
-
Heavy-gauge steel construction: Provides a durable, dent resilient structure.
-
Powder-baked paint: Creates a tough, scratch resistant finish (available in a wide selection of colors)
-
Lift off door hinges: Enable easy service access.
-
Stainless steel hinges and latches: Endures harsh weather conditions.
-
Recessed and lockable door handles: Minimize potential damage.
-
Rubber sealed access doors: Prevent water infiltration and minimizes noise
Options and Accessories:
-
Stainless steel, Aluminum, or Galvaneal construction
-
High wind certification
-
Gravity air outlet louver
-
Motorized air inlet louver with hood
-
Gravity air outlet louver
-
DC light package
-
Plexiglas panel viewing window
-
Sub base and cross member for generator set
-
Motorized variable damper (air inlet)
-
Enclosure heater
-
Fuel transfer system
-
Load banks
-
Door holders
Tramont Enclosure 68dBA Sound Attenuated
Steel enclosure with formed panel construction that protects your gen-set from the elements and provides 68dBA sound attenuation at 23 feet.
Standard Features:
-
90° vertical air outlet hood: Redirects airflow to reduce noise.
-
Acoustic insulation listed to UL-94 HF1 for flammability.
-
Formed panel construction: Allows design flexibility without compromising building standards.
-
Bolted panels: Facilitate service, future modification, upgrades or field replacement.
-
Radiator ducted to enclosure air outlet: Prevents air recirculation within the enclosure.
-
Punched air inlet features internal baffle to minimize rain intrusion and is sized for maximum cooling airflow.
-
Punched air louvers: Accommodate alternator cooling air.
-
Pitched enclosure roof: Prevents water accumulation.
-
Heavy-gauge steel construction: Provides a durable, dent resilient structure.
-
Powder-baked paint: Creates a tough, scratch resistant finish (available in a wide selection of colors)
-
Lift off door hinges: Enable easy service access.
-
Stainless steel hinges and latches: Endures harsh weather conditions.
-
Recessed and lockable door handles: Minimize potential damage.
-
Rubber sealed access doors: Prevent water infiltration and minimizes noise
Options and Accessories:
-
Stainless steel, Aluminum, or Galvaneal construction
-
High wind certification
-
Gravity air outlet louver
-
Motorized air inlet louver with hood
-
Gravity air outlet louver
-
DC light package
-
Plexiglas panel viewing window
-
Sub base and cross member for generator set
-
Motorized variable damper (air inlet)
-
Enclosure heater
-
Fuel transfer system
-
Load banks
-
Door holders
Tramont Enclosure Level 1 Sound Attenuated
Steel enclosure with modular panel construction that protect your gen-set from the elements and provide 15dBA noise reduction up to 23 feet.
Standard Features:
-
90° vertical air inlet and outlet hoods: Redirects air to reduce noise.
-
Level 1 Sound-attenuated: 15 dBA sound reduction @ 23 feet, 2" acoustic insulation (mechanically restrained); listed to UL-94 HF1 for flammability.
-
Interchangeable modular panel construction: Allows design flexibility without compromising building standards.
-
Bolted panels: Facilitate service, future modification, upgrades or field replacement.
-
Radiator ducted to enclosure air outlet: Prevents air recirculation within the enclosure.
-
Pitched (16:1) enclosure roof: Prevents water accumulation.
-
Heavy-gauge steel construction: Provides a durable, dent resistant structure.
-
Powder-baked paint: Creates a tough, scratch resistant finish (available in a wide selection of colors)
-
Lift off door hinges and radiator fill panel: Enable easy service access.
-
Stainless steel hinges and latches: Endures harsh weather conditions.
-
Recessed and lockable door handles: Minimize potential damage.
-
Rubber sealed access doors: Prevent water infiltration and minimize noise
Options and Accessories:
-
Stainless steel, Aluminum, or Galvaneal construction
-
High wind certification
-
Gravity air outlet louver
-
Motorized air intake louver
-
Motorized air outlet louver
-
120 VAC interior lighting with on/off switch
-
AC load center 120/240 single phase
-
DC light package
-
Plexiglas panel viewing window
-
Sub base and cross member for generator set
-
Motorized variable damper (air inlet and air outlet)
-
Enclosure heater
-
Fuel transfer system
-
Load banks
-
Door holders
Tramont Enclosure Level 2 Sound Attenuated
Steel enclosures with modular panel construction that protect your gen-set from the elements and provide 25 dBA noise reduction up to 23 feet.
Standard Features:
-
90° vertical air inlet and outlet hoods: Redirects air to reduce noise.
-
Level 2 sound attenuated: 25 dBA sound reduction @ 23 feet 4" acoustic insulation (mechanically restrained); listed to UL-94 HF1 for flammability.
-
Perforated interior liner: Improved aesthetics and sound attenuation.
-
Punched air louvers: Accommodates alternator cooling air.
-
Interchangeable modular panel construction: Allows design flexibility without compromising building standards.
-
Bolted panels: Facilitate service, future modification, upgrades or field replacement.
-
Radiator ducted to enclosure air outlet: Prevents air recirculation within the enclosure.
-
Pitched (16:1) enclosure roof: Prevents water accumulation.
-
Heavy gauge steel construction: Provides a durable, dent resistant structure.
-
Powder baked paint: Creates a tough, scratch resistant finish (available in a wide selection of colors).
-
Lift off door hinges and radiator fill panel: Enable easy service access.
-
Stainless steel hinges and latches: Endure harsh weather conditions.
-
Recessed and lockable door handles: Minimize potential damage.
-
Rubber sealed access doors: Prevent water infiltration and minimize noise.
Options and Accessories:
-
Stainless steel, Aluminum, or Galvaneal construction
-
High wind certification
-
Gravity air outlet louver
-
Motorized air intake louver
-
Motorized air outlet louver
-
120 VAC interior lighting with on/off switch
-
AC load center 120/240 single phase
-
DC light package
-
Plexiglas panel viewing window
-
Sub-base and cross member for generator set
-
Motorized variable damper (air inlet and air outlet)
-
Enclosure heater
-
Fuel transfer system
-
Load banks
-
Door holders

Tramont Gen-set Enclosures